# Anderson Residence > A QRchive archive: the permanent record behind one sticker. Everything below is what anyone who scans the sticker can see, laid out for an AI assistant to read. Human page: https://qrchive.ca/docs/QR-101833-JAR39 ## About this archive - Address: Sproat Lake, British Columbia, Canada - What it is: Uniform dispersal using timed dosing to an at grade rock aggregate sand lined seepage bed with passive ventilation. - Archive type: Septic - Unlocked: 2026-04-24 - Serviced by: QRchive - Files: 46 - Archive ID: QR-101833 ## Contacts - Septic emergency: 24-Hour Emergency Pump-Out · 250-555-0100 - Property owner: Mr. Anderson · 250-555-0142 · demo-owner@qrchive.ca ## Files ### Documents - [Pump chamber drawing: Canwest RKP1000](https://qrchive.ca/api/files/aace2cce-e736-4c55-8160-7e4b712d6a56) — PDF · added 2026-05-26 · 72 KB · appendix: Equipment manuals · added by the owner · No text inside this PDF (a scan or drawing). Open the file. - [Level sensor install guide: SJE Rhombus C-Level](https://qrchive.ca/api/files/735196d9-59ed-499a-8e7f-937522b00a67) — PDF · added 2026-05-26 · 433 KB · appendix: Equipment manuals · added by the owner · text: https://qrchive.ca/api/files/735196d9-59ed-499a-8e7f-937522b00a67/text (3,828 characters, printed in full below) - [Effluent pump manual: Myers ME50](https://qrchive.ca/api/files/f8af37dd-6a0d-4ba4-8f7f-c7b33b7aa184) — PDF · added 2026-05-26 · 954 KB · appendix: Equipment manuals · added by the owner · text: https://qrchive.ca/api/files/f8af37dd-6a0d-4ba4-8f7f-c7b33b7aa184/text (36,311 characters) - [Control panel manual: SJE Rhombus IFS](https://qrchive.ca/api/files/b0d95ae5-381d-4a7c-b130-876eff16855f) — PDF · added 2026-05-26 · 873 KB · appendix: Equipment manuals · starred by the owner · added by the owner · text: https://qrchive.ca/api/files/b0d95ae5-381d-4a7c-b130-876eff16855f/text (25,809 characters) - [Maintenance checklist](https://qrchive.ca/api/files/600f43c1-31b6-435d-90cb-2a0a85c444ea) — PDF · added 2026-05-26 · 73 KB · starred by the owner · added by the owner · text: https://qrchive.ca/api/files/600f43c1-31b6-435d-90cb-2a0a85c444ea/text (8,552 characters, printed in full below) - [Design drawing: dispersal field](https://qrchive.ca/api/files/3e2bb9ff-353e-470c-a7b6-50379f65e36e) — PDF · added 2026-05-26 · 823 KB · starred by the owner · added by the owner · text: https://qrchive.ca/api/files/3e2bb9ff-353e-470c-a7b6-50379f65e36e/text (1,501 characters, printed in full below) - [Design drawing: tanks](https://qrchive.ca/api/files/5ef73c2c-4ba1-4ec1-99ca-6d6522c72706) — PDF · added 2026-05-26 · 295 KB · starred by the owner · added by the owner · text: https://qrchive.ca/api/files/5ef73c2c-4ba1-4ec1-99ca-6d6522c72706/text (663 characters, printed in full below) - [Homeowner guide: Let's Get Septic Smart](https://qrchive.ca/api/files/fed59b42-72b2-4025-8de3-aeca3895ec17) — PDF · added 2026-05-26 · 483 KB · starred by the owner · added by the owner · text: https://qrchive.ca/api/files/fed59b42-72b2-4025-8de3-aeca3895ec17/text (24,095 characters) ### Photos - [Finished site overview](https://qrchive.ca/api/files/1117a241-b544-4dee-84a6-48e7eebcbbbe) — photo · added 2026-07-24 · 5.7 MB · appendix: Install photos · added by the owner - [Float switch bracket](https://qrchive.ca/api/files/0dc2e89b-f432-473b-8e27-52abf5e50175) — photo · added 2026-07-24 · 4.1 MB · appendix: Install photos · added by the owner - [Concrete tank opening](https://qrchive.ca/api/files/98e9c9b9-881a-4109-9623-c240a4c8740d) — photo · added 2026-07-24 · 6.4 MB · appendix: Install photos · added by the owner - [Simplex panel wiring](https://qrchive.ca/api/files/81d1d0c6-23c0-4baf-ac31-177879877acf) — photo · added 2026-07-24 · 4.4 MB · appendix: Install photos · added by the owner - [Tank tee closeup](https://qrchive.ca/api/files/7d44dc58-ff53-4651-95db-226d2ae7e2d2) — photo · added 2026-07-24 · 6.6 MB · appendix: Install photos · added by the owner - [Open tank riser](https://qrchive.ca/api/files/9e5b8d14-71c8-49ec-8c2d-14e407092721) — photo · added 2026-07-24 · 7.2 MB · appendix: Install photos · added by the owner - [Pump riser wiring](https://qrchive.ca/api/files/b97776af-34e6-41a5-ba87-662098297177) — photo · added 2026-07-24 · 7.3 MB · appendix: Install photos · added by the owner - [Override off time](https://qrchive.ca/api/files/d3c3eef3-c678-471f-81ab-6936a339d909) — photo · added 2026-07-24 · 1.8 MB · appendix: Install photos · added by the owner - [Override on time](https://qrchive.ca/api/files/7ba3e7b2-b4bf-4486-80f5-1d52a27177f2) — photo · added 2026-07-24 · 1.8 MB · appendix: Install photos · added by the owner - [Pump off time](https://qrchive.ca/api/files/bc63fa30-fd45-4104-a7f5-9da029ffab0e) — photo · added 2026-07-24 · 1.8 MB · appendix: Install photos · added by the owner - [Pump on time](https://qrchive.ca/api/files/d664294e-4c71-47d5-b408-fecc7be9ca83) — photo · added 2026-07-24 · 1.8 MB · appendix: Install photos · added by the owner - [Control panel open](https://qrchive.ca/api/files/053a3005-0e5b-4fca-b21b-7b4fdcbc0645) — photo · added 2026-07-24 · 4.3 MB · appendix: Install photos · added by the owner - [Mound vent pipes](https://qrchive.ca/api/files/27529598-2afa-4d2c-af7d-f208a4d6dd2f) — photo · added 2026-07-24 · 10.0 MB · appendix: Install photos · added by the owner - [Mound cleanout lids](https://qrchive.ca/api/files/86ec16f5-e774-4325-86a1-838fb33df060) — photo · added 2026-07-24 · 10.5 MB · appendix: Install photos · added by the owner - [Mound wide view](https://qrchive.ca/api/files/d7365c3d-2904-42e5-b633-32bfcac1e15a) — photo · added 2026-07-24 · 9.5 MB · appendix: Install photos · added by the owner - [Pump chamber interior](https://qrchive.ca/api/files/573a241c-5d64-4349-ae4d-df32eac4910e) — photo · added 2026-07-24 · 6.3 MB · appendix: Install photos · added by the owner - [Tank lids overview](https://qrchive.ca/api/files/d2fd5556-6629-4cbc-a582-671bb44b0b98) — photo · added 2026-07-24 · 9.8 MB · appendix: Install photos · added by the owner - [Pump discharge valve](https://qrchive.ca/api/files/02ceb1e5-4bd8-4777-920d-d110cc0df407) — photo · added 2026-07-24 · 7.4 MB · appendix: Install photos · added by the owner - [Tank risers backfill](https://qrchive.ca/api/files/bc34075c-51bf-4924-9d56-b9818673f97a) — photo · added 2026-07-24 · 11.1 MB · appendix: Install photos · added by the owner - [Trench toward house](https://qrchive.ca/api/files/fa8ec0b3-f6ef-4370-bfc3-b65d2f5a8d6d) — photo · added 2026-07-24 · 10.9 MB · appendix: Install photos · added by the owner - [Supply line trench](https://qrchive.ca/api/files/0561558f-5e60-48cb-b00e-d38400cf9d7f) — photo · added 2026-07-24 · 11.8 MB · appendix: Install photos · added by the owner - [Sand cap cleanouts](https://qrchive.ca/api/files/ab1bf84b-c066-4f6a-ba7a-20973829f577) — photo · added 2026-07-24 · 4.9 MB · appendix: Install photos · added by the owner - [Corrugated pipe layout](https://qrchive.ca/api/files/6576d19f-160f-4809-bdb1-092501e6830f) — photo · added 2026-07-24 · 12.0 MB · appendix: Install photos · added by the owner - [Scarified field area](https://qrchive.ca/api/files/1ef0111a-c058-4d76-82a0-37c311b4cade) — photo · added 2026-07-24 · 13.0 MB · appendix: Install photos · added by the owner - [Gravel bed overview](https://qrchive.ca/api/files/46b18649-f648-4b34-85dc-80bb1d6f2432) — photo · added 2026-07-24 · 5.0 MB · appendix: Install photos · added by the owner - [Laterals with cleanouts](https://qrchive.ca/api/files/e7b3fa03-e300-432d-8a0e-db963ae99522) — photo · added 2026-07-24 · 9.5 MB · appendix: Install photos · added by the owner - [Laterals on gravel](https://qrchive.ca/api/files/cc418474-2249-4135-9187-1a0381b928bc) — photo · added 2026-07-24 · 9.9 MB · appendix: Install photos · added by the owner - [Scarified soil surface](https://qrchive.ca/api/files/a4ad5fd2-1624-4c0a-9be7-301565e65a88) — photo · added 2026-07-24 · 12.0 MB · appendix: Install photos · added by the owner - [Sand fill placed](https://qrchive.ca/api/files/b0999bb0-b276-4e78-b8a0-c19c090d6a1a) — photo · added 2026-05-26 · 5.3 MB · appendix: Install photos · added by the owner - [Level settings screen](https://qrchive.ca/api/files/ed10c64a-5875-4d33-b994-6b24c9673c38) — photo · added 2026-05-26 · 2.1 MB · appendix: Install photos · added by the owner - [Pump cycle counts](https://qrchive.ca/api/files/cb411067-f799-412d-b3e6-7cb543a9a91b) — photo · added 2026-05-26 · 1.9 MB · appendix: Install photos · added by the owner - [Lids and panel](https://qrchive.ca/api/files/195b57d6-87cf-49f9-bbf6-d60be58aaffa) — photo · added 2026-05-26 · 10.1 MB · appendix: Install photos · added by the owner - [Finished mound](https://qrchive.ca/api/files/59d53b00-986e-40c9-9bf0-c973dabd9c5a) — photo · added 2026-05-26 · 9.0 MB · appendix: Install photos · added by the owner - [Effluent filter riser](https://qrchive.ca/api/files/d68033dd-7932-40f1-a115-a3856fab3f4f) — photo · added 2026-05-26 · 4.7 MB · appendix: Install photos · added by the owner - [Control panel mounted](https://qrchive.ca/api/files/89f292bf-da59-43ae-94e8-43d7094e7516) — photo · added 2026-05-26 · 8.0 MB · appendix: Install photos · added by the owner - [Finished sand cap](https://qrchive.ca/api/files/c67add8c-1e3f-4855-a3fa-931a24a310f7) — photo · added 2026-05-26 · 4.9 MB · appendix: Install photos · added by the owner - [Laterals side view](https://qrchive.ca/api/files/dee03df9-54db-466c-afe2-a6d21f444f10) — photo · added 2026-05-26 · 5.0 MB · appendix: Install photos · added by the owner ### Videos - [Tank riser video](https://qrchive.ca/api/files/586743bb-9e87-4d8b-8501-0e7673117db3) — video · added 2026-07-24 · 21.7 MB · appendix: Install photos · added by the owner ## Text from the PDFs Text copied word for word from inside each PDF by software. No person wrote or checked it. The PDF is the record: if the two disagree, the PDF is right. ### Level sensor install guide: SJE Rhombus C-Level PDF: https://qrchive.ca/api/files/735196d9-59ed-499a-8e7f-937522b00a67 ~~~text [Page 1] C-Level™ Sensor Installation Instructions SPECIFICATIONS • Measuring Range: CL40 - sensing range up to 40 inches (101.6 cm) CL100 - sensing range up to 100 inches (254 cm) • Accuracy: 5% Full Scale • Operating Temp: 32-122°F (0-50°C) • Output: Variable Frequency Signal • Input Power: 12 VDC 100 mA max. • IP Rating: IP 68 for permanent submersion • Wetted Materials: • Sensor Housing: PVC, 2.00” diameter x 5.35” length (51mm x 136mm) • Diaphragm: VITON®, 1.25” diameter (32mm) • Cable: TPE, 22 AWG - 3 conductor shielded with vent tube • Hose Clamp: 18-8 stainless steel Viton® is a trademark of E. I. DuPont de Nemours and Company Corporation • The vent tube opening must be kept in a clean and dry environment. Run the level sensor cable all the way to the control panel. Ensure proper sealing of conduits as to prevent gases and moisture from entering the control panel. Do not terminate in the wet well, even in a junction box. • Do NOT bend cable to a radius smaller than 1.5 inches (38mm) to avoid kinking the vent tube. • Do NOT press against the sensor diaphragm. • Do NOT support sensor by the cable. • Do NOT splice cable. Continuous level measurement in sewage and effluent lift stations, stormwater pump stations, non-potable water systems, tanks, wet wells, and reservoirs. 1079740B 07/23 IMPORTANT INFORMATION APPLICATIONS ELECTRICAL SHOCK HAZARD Disconnect power before installing or servicing this product. A qualified service person must install and service this product according to applicable electrical and plumbing codes. EXPLOSION OR FIRE HAZARD Do not use with flammable liquids. Install in accordance with ANSI/NFPA 70. Suitable for usage with intrinsically safe circuit extensions as defined by UL 698A. Failure to follow these precautions could result in serious injury or death. Replace product immediately if cable becomes damaged or severed. This product must be installed in accordance with National Electric Code, ANSI/NFPA 70 so as to prevent moisture from entering or accumulating within boxes, conduit bodies, fittings, or cable. Keep these instructions after installation. PN 1079740B 07/23 © 2023 SJE, Inc. All Rights Reserved. SJE RHOMBUS is a trademark of SJE, Inc. Phone: 800-746-6287 E-mail: techsupport@sjeinc.com www.sjerhombus SJE RHOMBUS® TWO-YEAR LIMITED WARRANTY Two-Year Limited Warranty. For complete terms and conditions, please visit: www.sjerhombus.com. [Page 2] 1 inch (2.5 cm) minimum from bottom of tank or from sludge 0 inch (0 cm) liquid level measured from approximately this point 4 inch (10.2 cm) minimum set level SHIELD: Connect to signal ground (low impedance)* RED: 12V power WHITE: Variable data signal VENT TUBE * If noise is observed in the frequency response, unplug the shield connection. BLACK: Ground Position sensor at appropriate location on pipe and secure sensor using provided hose clamp. Determine the submergence depth and operating level ranges. Terminate sensor cable in the control panel, connect wires to proper terminals as shown on the control panel schematic. Caution: Do not overtighten clamp or tie straps.WARNING: To prevent erroneous measurements, do not allow the sensor diaphragm to come into contact with solid objects or sludge. Do not use level measurements less than 4” (10.2 cm) for control or alarm purposes (dead band). Caution: If the level sensor wires are not connected properly, the C-Level™ signal output will not be correct. Level sensor and float cables need to run in separate conduit from pump and power cables. Tie Straps WARNING: DO NOT kink or place cable under hose clamp. Doing so may cause sensor to fail. WARNING: DO NOT support sensor by the cable. Redundant off float (recommended) High water alarm float (recommended) Functionally test the level measurement and ensure proper operation of the system by filling the tank. ~~~ ### Maintenance checklist PDF: https://qrchive.ca/api/files/600f43c1-31b6-435d-90cb-2a0a85c444ea ~~~text [Page 1] Date: Provider: Owner: System Type: Type 1 Sand Mound (Micro-Time Dosed) DDF: 2300 L/day ADF: 1150 L/day Components: Dispersal: Section Check Item Verification Task ☐ Pass / ☐ Fail / Notes Hazards Be aware of electrical hazards, tripping/falling hazards from open lids, protect bystanders, kids, dogs, etc. ☐ OK ☐ Action ☐ N/A Tank Protection Confirm continued protection of tanks — no traffic or structures over tanks, suitable surface drainage ☐ OK ☐ Action ☐ N/A Field Protection Confirm continued protection of dispersal field — no structures, no heavy traffic, appropriate vegetation/landscaping, no erosion ☐ OK ☐ Action ☐ N/A Surface No ponding, odors, or breakout risk over bed; cover soil intact and graded to shed runoff ☐ OK ☐ Action ☐ N/A Baffles Check alignment, condition, and proper operation of inlet and outlet baffles ☐ OK ☐ Action ☐ N/A FOG / Filter Clean fats/oil/grease from inlet baffle. Discuss any usage issues with owner. ☐ OK ☐ Action ☐ N/A Trickle Flow Confirm no trickle flows when fixtures off (no leaking toilets, dripping faucets, groundwater infiltration) ☐ OK ☐ Action ☐ N/A Sludge / Scum Measure sludge + scum: must be ≤ ⅓ of first-compartment volume. Pump out only if exceeded. ☐ OK ☐ Action ☐ N/A Baffles Check alignment, condition, and proper operation of inlet and outlet baffles ☐ OK ☐ Action ☐ N/A FOG / Filter Clean fats/oil/grease from inlet baffle. Inspect and clean PL250 effluent filter. Discuss any usage issues with owner. ☐ OK ☐ Action ☐ N/A Sludge / Scum Measure sludge + scum: must be ≤ ⅓ of first-compartment volume of Galcon RKS1400LP/2. Pump out only if exceeded. ☐ OK ☐ Action ☐ N/A Solids Assess solids in bottom of pump chamber — should be little/none, no foreign objects. Inspect effluent: type 1 characteristics. ☐ OK ☐ Action ☐ N/A Piping Confirm leak-free union and all piping in chamber. Note anti- siphon / air-removal orifice on discharge piping. ☐ OK ☐ Action ☐ N/A Conduit Seal Confirm sealing of electrical conduit from control panel to pump chamber (no moisture/gas passage to panel) ☐ OK ☐ Action ☐ N/A Floats / Pump Pull and clean control floats and exposed pump/wiring. Test redundant HLA and redundant Off floats. Test external alarm test/silence buttons. ☐ OK ☐ Action ☐ N/A Leaks / Breakout Inspect dispersal area for any signs of leaks, surfacing effluent, or breakout ☐ OK ☐ Action ☐ N/A Obs Ports Inspect 2× infiltrative-surface and 2× basal observation ports (4" Sch 40 PVC). Note any standing water or excessive ponding. ☐ OK ☐ Action ☐ N/A Vents Inspect 2× Big 'O' passive vent risers — gooseneck and bug screens intact, no obstructions ☐ OK ☐ Action ☐ N/A SECTION 1: PRE-SERVICE NOTES & VISUAL INSPECTION LIFT TANK LS: 700 IG concrete (2 ch, existing) → Myers 10MD (115V, ½ HP) on Rhombus NEXT panel | ST: Galcon RKS1400LP/2 w/ PL250 | PC: Galcon RKP1000LP (4546 L) | Field Pump: Myers ME 50 (230V, ½ HP) | Field Panel: SJE Rhombus IFS Simplex SEPTIC TANK GENERAL DISPERSAL MAINTENANCE CHECKLIST — TYPE 1 SAND MOUND SEEPAGE BED SYSTEM Sand mound seepage bed 4.2 × 14.0 m (1 zone, end-fed) | 6 laterals × 14 m (1.25" Sch 40 PVC), 66 cm OC, 45 cm to edge | 108 orifices (⅛" @ 78 cm, 12 o'clock w/ Polylok shields) | 30 cm mound sand + 30 cm pea gravel + 4 obs ports + 2× Big 'O' passive vent PUMP CHAMBER [Page 2] MAINTENANCE CHECKLIST — TYPE 1 SAND MOUND SEEPAGE BED SYSTEM Panel Condition SJE Rhombus IFS Simplex: weatherproof, accessible, no corrosion, mounting secure ☐ OK ☐ Action ☐ N/A Manual Override Test the manual pump override function inside the control panel ☐ OK ☐ Action ☐ N/A Panel Records Record cycle counts, elapsed run time, float errors, alarm counts via In-Site ☐ OK ☐ Action ☐ N/A Flow vs. ADF Cycles × 82 L/dose ≤ 1150 L/day ADF (DDF 2300 L/day). Flag if exceeding. ☐ OK ☐ Action ☐ N/A Lift Station Verify Lift Station (Myers 10MD on Rhombus NEXT) — HLA + on/off floats, alarm function, demand-dose cycling ☐ OK ☐ Action ☐ N/A Concerns Discuss any concerns with owner — alarms, smells, slow drains, system usage changes ☐ OK ☐ Action ☐ N/A Recommendations Provide owner with recommendations or follow-up actions arising from this maintenance visit ☐ OK ☐ Action ☐ N/A Photos Photos of components, observation ports, and any issues identified ☐ OK ☐ Action ☐ N/A Section Check Item Verification Task ☐ Pass / ☐ Fail / Notes Tanks Inspect all 3 tanks for leaks (lift station, septic tank, pump chamber). Watertight at risers/seams. ☐ OK ☐ Action ☐ N/A Piping Check transport main, pressure main, and manifold connections under pressure for leaks ☐ OK ☐ Action ☐ N/A Pressure Main Flush 2" main w/ lateral valves closed, manifold cleanout open ☐ OK ☐ Action ☐ N/A Laterals Flush all six 1.25" laterals individually, distal cleanout caps off ☐ OK ☐ Action ☐ N/A Manual Test Manually activate pump (override floats if needed); confirm pump operation ☐ OK ☐ Action ☐ N/A Timed Dosing Pump activates on timer (Override 51 min @ DDF / Primary 102 min @ ADF), shuts off after 23 s ☐ OK ☐ Action ☐ N/A Dose Volume Dose volume measured against design (82 L). Verify by drawdown ≈ 2 cm at 51 L/cm. ☐ OK ☐ Action ☐ N/A Check Valve No siphoning/backflow (check valve functional) ☐ OK ☐ Action ☐ N/A Section 1 Notes / Issues: OWNER INTERFACE ELECTRICAL & CONTROLS FLUSH DISPERSAL SECTION 2: PERFORMANCE TESTING & FIELD FLUSH LEAK TESTING Use field-pump dosing to flush components, verify dose volume, and run squirt test before close-out. PUMP & DOSING [Page 3] MAINTENANCE CHECKLIST — TYPE 1 SAND MOUND SEEPAGE BED SYSTEM Control Setting Design (cm) C-Level / Float (cm) As-Found (cm) High Level Alarm 66 C-Level: 50 | Float: 76 Override Timer Enable 71 C-Level: 45 | Float: n/a Primary Timer Enable 35 C-Level: 20 | Float: n/a Redundant Off / Low Level 30 C-Level: 10 | Float: 25 Dose Timer (On) 23 s Run time per dose (constant ADF & DDF) Rest Timer (Off) ADF: 102 min DDF: 51 min Primary 102 min @ ADF; Override 51 min @ DDF Section Check Item Verification Task ☐ Pass / ☐ Fail / Notes Float Function Raise/lower each float (HLA + Off) to simulate levels — confirm pump and alarm responses match ☐ OK ☐ Action ☐ N/A C-Level Reading Confirm C-Level transducer reading matches measured liquid depth − 15 cm (offset) ☐ OK ☐ Action ☐ N/A Alarm Test Simulate high water — alarm activates (light/horn). Test alarm- silence button. ☐ OK ☐ Action ☐ N/A Auto Mode Confirm AUTO is set for both pump and alarm before leaving site ☐ OK ☐ Action ☐ N/A Reset Errors Clear/log any error or alarm history; document elapsed run time and cycle count ☐ OK ☐ Action ☐ N/A Filter Clean Zabel A300 12"×20" — pull, hose off, inspect for damage/clogging, reinstall ☐ OK ☐ Action ☐ N/A SmartFilter Alarm Test Polylok SmartFilter Control Switch — wired to high-level alarm input on field-pump panel ☐ OK ☐ Action ☐ N/A Distribution Even distribution across all 6 laterals (1 zone, end-fed) ☐ OK ☐ Action ☐ N/A Squirt Test Install temp 1/8" orifice caps at lateral cleanouts; squirt test with all valves open. Record heights: ☐ OK ☐ Action ☐ N/A Remove Caps Remove drilled test caps; ensure all cleanout caps in place; confirm all lateral valves OPEN ☐ OK ☐ Action ☐ N/A Obs Ports Re-inspect obs ports post-flush — note any new ponding ☐ OK ☐ Action ☐ N/A BED TEST Section 2 Notes / Issues: All heights from inside bottom of pump chamber. C-Level transducer offset = 15 cm above tank bottom (C-Level reading = float setpoint − 15 cm). Confirm setpoints match design or r FLOAT & CONTROL PANEL VERIFICATION — AS-FOUND vs. AS-RESET FLOAT & PANEL EFFLUENT FILTER [Page 4] MAINTENANCE CHECKLIST — TYPE 1 SAND MOUND SEEPAGE BED SYSTEM Section Check Item Verification Task ☐ Pass / ☐ Fail / Notes Lids Secured After service, ensure all tank lids/risers properly secured (LS, ST, PC) ☐ OK ☐ Action ☐ N/A Site Tidy Tools/equipment removed; valve boxes covered; site left clean for owner ☐ OK ☐ Action ☐ N/A Owner Brief Brief owner on findings, recommendations, and next maintenance interval ☐ OK ☐ Action ☐ N/A Records Update maintenance log with cycle count, run time, dose volume, alarms, panel readings ☐ OK ☐ Action ☐ N/A Reporting If ROWP problems arise, submit annual report to Island Health (per SSR / ROWP duties) ☐ OK ☐ Action ☐ N/A Signature: Date: System has been serviced per the maintenance plan and is operating within design parameters. Any departures or follow-up actions are documented in the Notes/Issues sections above. FINAL SIGN-OFF Follow-up actions required (if any): SECTION 3: DOCUMENTATION & CLOSE-OUT _______________________________________ , Maintenance Provider CLOSE-OUT Section 3 Notes / Issues: ~~~ ### Design drawing: dispersal field PDF: https://qrchive.ca/api/files/3e2bb9ff-353e-470c-a7b6-50379f65e36e ~~~text [Page 1] DESIGN DETAILS: SECTION VIEW OF DISPERSAL FIELD DETAILS LATERAL PIPE LANDSCAPE BOX NDS PRO 150 mm FINISHED GRADE LATERAL CLEAN OUT CLEAN OUT ACCESS PORT 50 mm (2.0 in) SCH. 40 PVC TRANSPORT PIPE FROM PUMP CHAMBER 32 mm (1.25 in) SCH. 40 PVC LATERAL 32 mm (1.25 in) SCH. 40 PVC THREADED END CAP 32 mm (1.25 in) SCH. 40 LONG SWEEP 90 ELBOW OR 2x 45 ELBOW 50 mm (2.0 in) SCH. 40 LONG SWEEP 90 ELBOW OR 2x 45 ELBOW 50 mm (2.0 in) SCH. 40 PVC THREADED END CAP ORIFICES LOCATED ON LATERALS @ 12 O'CLOCK POSITION. FIRST AND LAST ORIFICES AT 1/2 SPACING FROM THE MANIFOLD AND END CLEANOUT. LATERALS TO BE LAID LEVEL (+/- 5cm) 4" BIG 'O' PERFORATED PIPE BEDDED IN 12" OF 1/2" WASHED PEA GRAVEL 1.25" PVC DISPERSAL LATERALS 2" PVC PRESSURE MANIFOLD 4" SCH 40 PVC 90 DEG ELBOW 2x 4" SCH 40 PVC 90 DEG ELBOWS STAINLESS STEEL BUG SCREEN 4" SCH 40 PVC VERTICAL RISER MINIMUM OF 60 cm ABOVE GRADE PVC GOOSENECK BASE BEDDED IN COMPACTED MOUND SAND MEDIA OR NATIVE SANDY LOAM COVER SOIL 390 mm 780 mm 390 mm 14.0 m 780 mm 32 mm (1.25 in) SCH. 40 PVC THREADED END CAP 32 mm (1.25 in) SCH. 40 LONG SWEEP 90 ELBOW OR 2x 45 ELBOW SECTION VIEW OF LATERAL PIPE SECTION VIEW OF PASSIVE VENTILATION 50 mm (2.0 in) SCH. 40 PVC MANIFOLD MANIFOLD CONNECTION TO LATERAL PIPES POLYLOK ORIFICE SHIELD 18 PER INDIVIDUAL LATERAL (x6 LATERALS) 32 mm (1.25 in) BALL VALVE TO BE ACCESSIBLE FROM SURFACE BEDDED IN PEA GRAVEL BASE COVER SOIL 50 mm (2.0 in) SCH. 40 TEE AND 2.0 in x 1.25 REDUCING BUSHING 50 mm (2.0 in) SCH. 40 PVC MANIFOLD ~~~ ### Design drawing: tanks PDF: https://qrchive.ca/api/files/5ef73c2c-4ba1-4ec1-99ca-6d6522c72706 ~~~text [Page 1] DESIGN DETAILS: SECTION VIEW OF TANK DETAILS PUMP CHAMBER: RKP1000LP - 1 CHAMBER SEPTIC TANK: RKS1000LP/2 - 2 CHAMBER OUTLET TO FIELD INLET OUTLET TO PUMP CHAMBER INLET OFF FLOAT HIGH LEVEL ALARM FLOAT C-LEVEL SENSOR CHECK VALVE ZABEL A300 1/32" 12"x20" EFFLUENT FILTER PVC SCH. 40 32 mm (1.25 in) FLOAT TREE PVC SCH 40 BALL VALVE PVC SCH. 40 UNION 3/16" ORIFICE HOLE LIFT STATION: 700 IG 2 CHAMBER OUTLET TO FIELD SEPTIC TANK INLET HIGH LEVEL ALARM FLOAT ON/OFF FLOAT FLOAT SWITCH CABLE WEIGHT TETHER LENGTH 10 CM (4 INCHES) ZABEL A300 FILTER CARTRIDGE CHECK VALVE PVC SCH 40 BALL VALVEPVC SCH. 40 UNION 3/16" ORIFICE HOLE FILTER ACCESS HANDLE FILTER SUPPORT ARM ~~~ ## Notes for AI assistants - The files are the record. This listing is a guide to them, generated from the archive when it was requested. - Open a file with its link. Where a PDF also has a text link, that link returns the text inside the PDF as plain text. Short documents are printed in full at the end of this listing. - Photos (37) and video (1) are listed by name only — nothing here describes what they show. Same listing as JSON: https://qrchive.ca/docs/QR-101833-JAR39/archive.json Generated 2026-10-16T15:26:50.417Z.