  "schema": "qrchive.archive/v1",
  "archive": {
    "id": "QR-101833",
    "page_url": "https://qrchive.ca/docs/QR-101833-JAR39",
    "markdown_url": "https://qrchive.ca/docs/QR-101833-JAR39/llms.txt",
    "json_url": "https://qrchive.ca/docs/QR-101833-JAR39/archive.json",
    "title": "Anderson Residence",
    "address": "Sproat Lake, British Columbia, Canada",
    "summary": "Uniform dispersal using timed dosing to an at grade rock aggregate sand lined seepage bed with passive ventilation.",
    "archive_type": "Septic",
    "unlocked": "2026-04-24",
    "kept_by": {
      "heading": "Serviced by",
      "name": "QRchive"
    }
  },
  "contacts": {
    "emergency": {
      "heading": "Septic emergency",
      "name": "24-Hour Emergency Pump-Out",
      "phone": "250-555-0100"
    },
    "property_owner": {
      "name": "Mr. Anderson",
      "phone": "250-555-0142",
      "email": "demo-owner@qrchive.ca"
    }
  },
  "sections": [
    {
      "heading": "Documents",
      "file_ids": [
        "aace2cce-e736-4c55-8160-7e4b712d6a56",
        "735196d9-59ed-499a-8e7f-937522b00a67",
        "f8af37dd-6a0d-4ba4-8f7f-c7b33b7aa184",
        "b0d95ae5-381d-4a7c-b130-876eff16855f",
        "600f43c1-31b6-435d-90cb-2a0a85c444ea",
        "3e2bb9ff-353e-470c-a7b6-50379f65e36e",
        "5ef73c2c-4ba1-4ec1-99ca-6d6522c72706",
        "fed59b42-72b2-4025-8de3-aeca3895ec17"
      ]
    },
    {
      "heading": "Photos",
      "file_ids": [
        "1117a241-b544-4dee-84a6-48e7eebcbbbe",
        "0dc2e89b-f432-473b-8e27-52abf5e50175",
        "98e9c9b9-881a-4109-9623-c240a4c8740d",
        "81d1d0c6-23c0-4baf-ac31-177879877acf",
        "7d44dc58-ff53-4651-95db-226d2ae7e2d2",
        "9e5b8d14-71c8-49ec-8c2d-14e407092721",
        "b97776af-34e6-41a5-ba87-662098297177",
        "d3c3eef3-c678-471f-81ab-6936a339d909",
        "7ba3e7b2-b4bf-4486-80f5-1d52a27177f2",
        "bc63fa30-fd45-4104-a7f5-9da029ffab0e",
        "d664294e-4c71-47d5-b408-fecc7be9ca83",
        "053a3005-0e5b-4fca-b21b-7b4fdcbc0645",
        "27529598-2afa-4d2c-af7d-f208a4d6dd2f",
        "86ec16f5-e774-4325-86a1-838fb33df060",
        "d7365c3d-2904-42e5-b633-32bfcac1e15a",
        "573a241c-5d64-4349-ae4d-df32eac4910e",
        "d2fd5556-6629-4cbc-a582-671bb44b0b98",
        "02ceb1e5-4bd8-4777-920d-d110cc0df407",
        "bc34075c-51bf-4924-9d56-b9818673f97a",
        "fa8ec0b3-f6ef-4370-bfc3-b65d2f5a8d6d",
        "0561558f-5e60-48cb-b00e-d38400cf9d7f",
        "ab1bf84b-c066-4f6a-ba7a-20973829f577",
        "6576d19f-160f-4809-bdb1-092501e6830f",
        "1ef0111a-c058-4d76-82a0-37c311b4cade",
        "46b18649-f648-4b34-85dc-80bb1d6f2432",
        "e7b3fa03-e300-432d-8a0e-db963ae99522",
        "cc418474-2249-4135-9187-1a0381b928bc",
        "a4ad5fd2-1624-4c0a-9be7-301565e65a88",
        "b0999bb0-b276-4e78-b8a0-c19c090d6a1a",
        "ed10c64a-5875-4d33-b994-6b24c9673c38",
        "cb411067-f799-412d-b3e6-7cb543a9a91b",
        "195b57d6-87cf-49f9-bbf6-d60be58aaffa",
        "59d53b00-986e-40c9-9bf0-c973dabd9c5a",
        "d68033dd-7932-40f1-a115-a3856fab3f4f",
        "89f292bf-da59-43ae-94e8-43d7094e7516",
        "c67add8c-1e3f-4855-a3fa-931a24a310f7",
        "dee03df9-54db-466c-afe2-a6d21f444f10"
      ]
    },
    {
      "heading": "Videos",
      "file_ids": [
        "586743bb-9e87-4d8b-8501-0e7673117db3"
      ]
    }
  ],
  "files": [
    {
      "id": "1117a241-b544-4dee-84a6-48e7eebcbbbe",
      "title": "Finished site overview",
      "file_name": "IMG_6655.JPG",
      "kind": "photo",
      "section": "Photos",
      "appendix": "Install photos",
      "added": "2026-07-24",
      "size_bytes": 5986236,
      "starred": false,
      "url": "https://qrchive.ca/api/files/1117a241-b544-4dee-84a6-48e7eebcbbbe",
      "text_status": null,
      "text_chars": null,
      "text_url": null,
      "text": null,
      "added_by": "added by the owner",
      "text_withheld": false
    },
    {
      "id": "0dc2e89b-f432-473b-8e27-52abf5e50175",
      "title": "Float switch bracket",
      "file_name": "IMG_6652.JPG",
      "kind": "photo",
      "section": "Photos",
      "appendix": "Install photos",
      "added": "2026-07-24",
      "size_bytes": 4267919,
      "starred": false,
      "url": "https://qrchive.ca/api/files/0dc2e89b-f432-473b-8e27-52abf5e50175",
      "text_status": null,
      "text_chars": null,
      "text_url": null,
      "text": null,
      "added_by": "added by the owner",
      "text_withheld": false
    },
    {
      "id": "98e9c9b9-881a-4109-9623-c240a4c8740d",
      "title": "Concrete tank opening",
      "file_name": "IMG_6650.JPG",
      "kind": "photo",
      "section": "Photos",
      "appendix": "Install photos",
      "added": "2026-07-24",
      "size_bytes": 6678867,
      "starred": false,
      "url": "https://qrchive.ca/api/files/98e9c9b9-881a-4109-9623-c240a4c8740d",
      "text_status": null,
      "text_chars": null,
      "text_url": null,
      "text": null,
      "added_by": "added by the owner",
      "text_withheld": false
    },
    {
      "id": "81d1d0c6-23c0-4baf-ac31-177879877acf",
      "title": "Simplex panel wiring",
      "file_name": "IMG_6648.JPG",
      "kind": "photo",
      "section": "Photos",
      "appendix": "Install photos",
      "added": "2026-07-24",
      "size_bytes": 4592696,
      "starred": false,
      "url": "https://qrchive.ca/api/files/81d1d0c6-23c0-4baf-ac31-177879877acf",
      "text_status": null,
      "text_chars": null,
      "text_url": null,
      "text": null,
      "added_by": "added by the owner",
      "text_withheld": false
    },
    {
      "id": "7d44dc58-ff53-4651-95db-226d2ae7e2d2",
      "title": "Tank tee closeup",
      "file_name": "IMG_6647.JPG",
      "kind": "photo",
      "section": "Photos",
      "appendix": "Install photos",
      "added": "2026-07-24",
      "size_bytes": 6889830,
      "starred": false,
      "url": "https://qrchive.ca/api/files/7d44dc58-ff53-4651-95db-226d2ae7e2d2",
      "text_status": null,
      "text_chars": null,
      "text_url": null,
      "text": null,
      "added_by": "added by the owner",
      "text_withheld": false
    },
    {
      "id": "9e5b8d14-71c8-49ec-8c2d-14e407092721",
      "title": "Open tank riser",
      "file_name": "IMG_6645.JPG",
      "kind": "photo",
      "section": "Photos",
      "appendix": "Install photos",
      "added": "2026-07-24",
      "size_bytes": 7584367,
      "starred": false,
      "url": "https://qrchive.ca/api/files/9e5b8d14-71c8-49ec-8c2d-14e407092721",
      "text_status": null,
      "text_chars": null,
      "text_url": null,
      "text": null,
      "added_by": "added by the owner",
      "text_withheld": false
    },
    {
      "id": "b97776af-34e6-41a5-ba87-662098297177",
      "title": "Pump riser wiring",
      "file_name": "IMG_6644.JPG",
      "kind": "photo",
      "section": "Photos",
      "appendix": "Install photos",
      "added": "2026-07-24",
      "size_bytes": 7658999,
      "starred": false,
      "url": "https://qrchive.ca/api/files/b97776af-34e6-41a5-ba87-662098297177",
      "text_status": null,
      "text_chars": null,
      "text_url": null,
      "text": null,
      "added_by": "added by the owner",
      "text_withheld": false
    },
    {
      "id": "d3c3eef3-c678-471f-81ab-6936a339d909",
      "title": "Override off time",
      "file_name": "IMG_6642.JPG",
      "kind": "photo",
      "section": "Photos",
      "appendix": "Install photos",
      "added": "2026-07-24",
      "size_bytes": 1852448,
      "starred": false,
      "url": "https://qrchive.ca/api/files/d3c3eef3-c678-471f-81ab-6936a339d909",
      "text_status": null,
      "text_chars": null,
      "text_url": null,
      "text": null,
      "added_by": "added by the owner",
      "text_withheld": false
    },
    {
      "id": "7ba3e7b2-b4bf-4486-80f5-1d52a27177f2",
      "title": "Override on time",
      "file_name": "IMG_6641.JPG",
      "kind": "photo",
      "section": "Photos",
      "appendix": "Install photos",
      "added": "2026-07-24",
      "size_bytes": 1835449,
      "starred": false,
      "url": "https://qrchive.ca/api/files/7ba3e7b2-b4bf-4486-80f5-1d52a27177f2",
      "text_status": null,
      "text_chars": null,
      "text_url": null,
      "text": null,
      "added_by": "added by the owner",
      "text_withheld": false
    },
    {
      "id": "bc63fa30-fd45-4104-a7f5-9da029ffab0e",
      "title": "Pump off time",
      "file_name": "IMG_6640.JPG",
      "kind": "photo",
      "section": "Photos",
      "appendix": "Install photos",
      "added": "2026-07-24",
      "size_bytes": 1844014,
      "starred": false,
      "url": "https://qrchive.ca/api/files/bc63fa30-fd45-4104-a7f5-9da029ffab0e",
      "text_status": null,
      "text_chars": null,
      "text_url": null,
      "text": null,
      "added_by": "added by the owner",
      "text_withheld": false
    },
    {
      "id": "d664294e-4c71-47d5-b408-fecc7be9ca83",
      "title": "Pump on time",
      "file_name": "IMG_6639.JPG",
      "kind": "photo",
      "section": "Photos",
      "appendix": "Install photos",
      "added": "2026-07-24",
      "size_bytes": 1896967,
      "starred": false,
      "url": "https://qrchive.ca/api/files/d664294e-4c71-47d5-b408-fecc7be9ca83",
      "text_status": null,
      "text_chars": null,
      "text_url": null,
      "text": null,
      "added_by": "added by the owner",
      "text_withheld": false
    },
    {
      "id": "053a3005-0e5b-4fca-b21b-7b4fdcbc0645",
      "title": "Control panel open",
      "file_name": "IMG_6637.JPG",
      "kind": "photo",
      "section": "Photos",
      "appendix": "Install photos",
      "added": "2026-07-24",
      "size_bytes": 4541701,
      "starred": false,
      "url": "https://qrchive.ca/api/files/053a3005-0e5b-4fca-b21b-7b4fdcbc0645",
      "text_status": null,
      "text_chars": null,
      "text_url": null,
      "text": null,
      "added_by": "added by the owner",
      "text_withheld": false
    },
    {
      "id": "27529598-2afa-4d2c-af7d-f208a4d6dd2f",
      "title": "Mound vent pipes",
      "file_name": "IMG_6635.JPG",
      "kind": "photo",
      "section": "Photos",
      "appendix": "Install photos",
      "added": "2026-07-24",
      "size_bytes": 10535697,
      "starred": false,
      "url": "https://qrchive.ca/api/files/27529598-2afa-4d2c-af7d-f208a4d6dd2f",
      "text_status": null,
      "text_chars": null,
      "text_url": null,
      "text": null,
      "added_by": "added by the owner",
      "text_withheld": false
    },
    {
      "id": "86ec16f5-e774-4325-86a1-838fb33df060",
      "title": "Mound cleanout lids",
      "file_name": "IMG_6634.JPG",
      "kind": "photo",
      "section": "Photos",
      "appendix": "Install photos",
      "added": "2026-07-24",
      "size_bytes": 10974574,
      "starred": false,
      "url": "https://qrchive.ca/api/files/86ec16f5-e774-4325-86a1-838fb33df060",
      "text_status": null,
      "text_chars": null,
      "text_url": null,
      "text": null,
      "added_by": "added by the owner",
      "text_withheld": false
    },
    {
      "id": "d7365c3d-2904-42e5-b633-32bfcac1e15a",
      "title": "Mound wide view",
      "file_name": "IMG_6589.JPG",
      "kind": "photo",
      "section": "Photos",
      "appendix": "Install photos",
      "added": "2026-07-24",
      "size_bytes": 9953811,
      "starred": false,
      "url": "https://qrchive.ca/api/files/d7365c3d-2904-42e5-b633-32bfcac1e15a",
      "text_status": null,
      "text_chars": null,
      "text_url": null,
      "text": null,
      "added_by": "added by the owner",
      "text_withheld": false
    },
    {
      "id": "573a241c-5d64-4349-ae4d-df32eac4910e",
      "title": "Pump chamber interior",
      "file_name": "IMG_6586.JPG",
      "kind": "photo",
      "section": "Photos",
      "appendix": "Install photos",
      "added": "2026-07-24",
      "size_bytes": 6579844,
      "starred": false,
      "url": "https://qrchive.ca/api/files/573a241c-5d64-4349-ae4d-df32eac4910e",
      "text_status": null,
      "text_chars": null,
      "text_url": null,
      "text": null,
      "added_by": "added by the owner",
      "text_withheld": false
    },
    {
      "id": "d2fd5556-6629-4cbc-a582-671bb44b0b98",
      "title": "Tank lids overview",
      "file_name": "IMG_6585.JPG",
      "kind": "photo",
      "section": "Photos",
      "appendix": "Install photos",
      "added": "2026-07-24",
      "size_bytes": 10252867,
      "starred": false,
      "url": "https://qrchive.ca/api/files/d2fd5556-6629-4cbc-a582-671bb44b0b98",
      "text_status": null,
      "text_chars": null,
      "text_url": null,
      "text": null,
      "added_by": "added by the owner",
      "text_withheld": false
    },
    {
      "id": "586743bb-9e87-4d8b-8501-0e7673117db3",
      "title": "Tank riser video",
      "file_name": "IMG_6582.MOV",
      "kind": "video",
      "section": "Videos",
      "appendix": "Install photos",
      "added": "2026-07-24",
      "size_bytes": 22765792,
      "starred": false,
      "url": "https://qrchive.ca/api/files/586743bb-9e87-4d8b-8501-0e7673117db3",
      "text_status": null,
      "text_chars": null,
      "text_url": null,
      "text": null,
      "added_by": "added by the owner",
      "text_withheld": false
    },
    {
      "id": "02ceb1e5-4bd8-4777-920d-d110cc0df407",
      "title": "Pump discharge valve",
      "file_name": "IMG_6581.JPG",
      "kind": "photo",
      "section": "Photos",
      "appendix": "Install photos",
      "added": "2026-07-24",
      "size_bytes": 7724272,
      "starred": false,
      "url": "https://qrchive.ca/api/files/02ceb1e5-4bd8-4777-920d-d110cc0df407",
      "text_status": null,
      "text_chars": null,
      "text_url": null,
      "text": null,
      "added_by": "added by the owner",
      "text_withheld": false
    },
    {
      "id": "bc34075c-51bf-4924-9d56-b9818673f97a",
      "title": "Tank risers backfill",
      "file_name": "IMG_5268.jpeg",
      "kind": "photo",
      "section": "Photos",
      "appendix": "Install photos",
      "added": "2026-07-24",
      "size_bytes": 11595929,
      "starred": false,
      "url": "https://qrchive.ca/api/files/bc34075c-51bf-4924-9d56-b9818673f97a",
      "text_status": null,
      "text_chars": null,
      "text_url": null,
      "text": null,
      "added_by": "added by the owner",
      "text_withheld": false
    },
    {
      "id": "fa8ec0b3-f6ef-4370-bfc3-b65d2f5a8d6d",
      "title": "Trench toward house",
      "file_name": "IMG_5267.jpeg",
      "kind": "photo",
      "section": "Photos",
      "appendix": "Install photos",
      "added": "2026-07-24",
      "size_bytes": 11387657,
      "starred": false,
      "url": "https://qrchive.ca/api/files/fa8ec0b3-f6ef-4370-bfc3-b65d2f5a8d6d",
      "text_status": null,
      "text_chars": null,
      "text_url": null,
      "text": null,
      "added_by": "added by the owner",
      "text_withheld": false
    },
    {
      "id": "0561558f-5e60-48cb-b00e-d38400cf9d7f",
      "title": "Supply line trench",
      "file_name": "IMG_5266.jpeg",
      "kind": "photo",
      "section": "Photos",
      "appendix": "Install photos",
      "added": "2026-07-24",
      "size_bytes": 12370538,
      "starred": false,
      "url": "https://qrchive.ca/api/files/0561558f-5e60-48cb-b00e-d38400cf9d7f",
      "text_status": null,
      "text_chars": null,
      "text_url": null,
      "text": null,
      "added_by": "added by the owner",
      "text_withheld": false
    },
    {
      "id": "ab1bf84b-c066-4f6a-ba7a-20973829f577",
      "title": "Sand cap cleanouts",
      "file_name": "IMG_5264.jpeg",
      "kind": "photo",
      "section": "Photos",
      "appendix": "Install photos",
      "added": "2026-07-24",
      "size_bytes": 5125337,
      "starred": false,
      "url": "https://qrchive.ca/api/files/ab1bf84b-c066-4f6a-ba7a-20973829f577",
      "text_status": null,
      "text_chars": null,
      "text_url": null,
      "text": null,
      "added_by": "added by the owner",
      "text_withheld": false
    },
    {
      "id": "6576d19f-160f-4809-bdb1-092501e6830f",
      "title": "Corrugated pipe layout",
      "file_name": "IMG_5220.jpeg",
      "kind": "photo",
      "section": "Photos",
      "appendix": "Install photos",
      "added": "2026-07-24",
      "size_bytes": 12624901,
      "starred": false,
      "url": "https://qrchive.ca/api/files/6576d19f-160f-4809-bdb1-092501e6830f",
      "text_status": null,
      "text_chars": null,
      "text_url": null,
      "text": null,
      "added_by": "added by the owner",
      "text_withheld": false
    },
    {
      "id": "1ef0111a-c058-4d76-82a0-37c311b4cade",
      "title": "Scarified field area",
      "file_name": "IMG_5210.jpeg",
      "kind": "photo",
      "section": "Photos",
      "appendix": "Install photos",
      "added": "2026-07-24",
      "size_bytes": 13676713,
      "starred": false,
      "url": "https://qrchive.ca/api/files/1ef0111a-c058-4d76-82a0-37c311b4cade",
      "text_status": null,
      "text_chars": null,
      "text_url": null,
      "text": null,
      "added_by": "added by the owner",
      "text_withheld": false
    },
    {
      "id": "46b18649-f648-4b34-85dc-80bb1d6f2432",
      "title": "Gravel bed overview",
      "file_name": "IMG_5242.jpeg",
      "kind": "photo",
      "section": "Photos",
      "appendix": "Install photos",
      "added": "2026-07-24",
      "size_bytes": 5238902,
      "starred": false,
      "url": "https://qrchive.ca/api/files/46b18649-f648-4b34-85dc-80bb1d6f2432",
      "text_status": null,
      "text_chars": null,
      "text_url": null,
      "text": null,
      "added_by": "added by the owner",
      "text_withheld": false
    },
    {
      "id": "e7b3fa03-e300-432d-8a0e-db963ae99522",
      "title": "Laterals with cleanouts",
      "file_name": "IMG_5238.jpeg",
      "kind": "photo",
      "section": "Photos",
      "appendix": "Install photos",
      "added": "2026-07-24",
      "size_bytes": 9925051,
      "starred": false,
      "url": "https://qrchive.ca/api/files/e7b3fa03-e300-432d-8a0e-db963ae99522",
      "text_status": null,
      "text_chars": null,
      "text_url": null,
      "text": null,
      "added_by": "added by the owner",
      "text_withheld": false
    },
    {
      "id": "cc418474-2249-4135-9187-1a0381b928bc",
      "title": "Laterals on gravel",
      "file_name": "IMG_5237.jpeg",
      "kind": "photo",
      "section": "Photos",
      "appendix": "Install photos",
      "added": "2026-07-24",
      "size_bytes": 10368636,
      "starred": false,
      "url": "https://qrchive.ca/api/files/cc418474-2249-4135-9187-1a0381b928bc",
      "text_status": null,
      "text_chars": null,
      "text_url": null,
      "text": null,
      "added_by": "added by the owner",
      "text_withheld": false
    },
    {
      "id": "a4ad5fd2-1624-4c0a-9be7-301565e65a88",
      "title": "Scarified soil surface",
      "file_name": "IMG_5211.jpeg",
      "kind": "photo",
      "section": "Photos",
      "appendix": "Install photos",
      "added": "2026-07-24",
      "size_bytes": 12543911,
      "starred": false,
      "url": "https://qrchive.ca/api/files/a4ad5fd2-1624-4c0a-9be7-301565e65a88",
      "text_status": null,
      "text_chars": null,
      "text_url": null,
      "text": null,
      "added_by": "added by the owner",
      "text_withheld": false
    },
    {
      "id": "aace2cce-e736-4c55-8160-7e4b712d6a56",
      "title": "Pump chamber drawing: Canwest RKP1000",
      "file_name": "rkp1000.pdf",
      "kind": "PDF",
      "section": "Documents",
      "appendix": "Equipment manuals",
      "added": "2026-05-26",
      "size_bytes": 74094,
      "starred": false,
      "url": "https://qrchive.ca/api/files/aace2cce-e736-4c55-8160-7e4b712d6a56",
      "text_status": "no_text",
      "text_chars": null,
      "text_url": null,
      "text": null,
      "added_by": "added by the owner",
      "text_withheld": false
    },
    {
      "id": "735196d9-59ed-499a-8e7f-937522b00a67",
      "title": "Level sensor install guide: SJE Rhombus C-Level",
      "file_name": "Rhombus-C-Level-Sensor-Install.pdf",
      "kind": "PDF",
      "section": "Documents",
      "appendix": "Equipment manuals",
      "added": "2026-05-26",
      "size_bytes": 443110,
      "starred": false,
      "url": "https://qrchive.ca/api/files/735196d9-59ed-499a-8e7f-937522b00a67",
      "text_status": "ok",
      "text_chars": 3828,
      "text_url": "https://qrchive.ca/api/files/735196d9-59ed-499a-8e7f-937522b00a67/text",
      "text": "[Page 1]\nC-Level™ Sensor\nInstallation Instructions\nSPECIFICATIONS\n• Measuring Range:\nCL40 - sensing range up to 40 inches (101.6 cm)\nCL100 - sensing range up to 100 inches (254 cm)\n• Accuracy: 5% Full Scale\n• Operating Temp: 32-122°F (0-50°C)\n• Output: Variable Frequency Signal\n• Input Power: 12 VDC 100 mA max.\n• IP Rating: IP 68 for permanent submersion\n• Wetted Materials:\n• Sensor Housing: PVC, 2.00” diameter x 5.35” length\n(51mm x 136mm)\n• Diaphragm: VITON®, 1.25” diameter (32mm)\n• Cable: TPE, 22 AWG - 3 conductor shielded with vent tube\n• Hose Clamp: 18-8 stainless steel\nViton® is a trademark of E. I. DuPont de Nemours and Company Corporation\n• The vent tube opening must be kept in a clean and dry\nenvironment. Run the level sensor cable all the way to the control\npanel. Ensure proper sealing of conduits as to prevent gases and\nmoisture from entering the control panel. Do not terminate in the\nwet well, even in a junction box.\n• Do NOT bend cable to a radius smaller than 1.5 inches (38mm) to\navoid kinking the vent tube.\n• Do NOT press against the sensor diaphragm.\n• Do NOT support sensor by the cable.\n• Do NOT splice cable.\nContinuous level measurement in sewage and effluent lift stations,\nstormwater pump stations, non-potable water systems, tanks, wet\nwells, and reservoirs.\n1079740B 07/23\nIMPORTANT INFORMATION\nAPPLICATIONS\nELECTRICAL SHOCK HAZARD\nDisconnect power before installing or servicing this product. A\nqualified service person must install and service this product\naccording to applicable electrical and plumbing codes.\nEXPLOSION OR FIRE HAZARD\nDo not use with flammable liquids. Install in accordance with\nANSI/NFPA 70. Suitable for usage with intrinsically safe circuit\nextensions as defined by UL 698A.\nFailure to follow these precautions could result in serious injury or death.\nReplace product immediately if cable becomes damaged or severed. This\nproduct must be installed in accordance with National Electric Code,\nANSI/NFPA 70 so as to prevent moisture from entering or accumulating\nwithin boxes, conduit bodies, fittings, or cable. Keep these instructions\nafter installation.\nPN 1079740B 07/23\n© 2023 SJE, Inc. All Rights Reserved.\nSJE RHOMBUS is a trademark of SJE, Inc.\nPhone: 800-746-6287\nE-mail: techsupport@sjeinc.com\nwww.sjerhombus\nSJE RHOMBUS® TWO-YEAR LIMITED WARRANTY\nTwo-Year Limited Warranty.\nFor complete terms and conditions, please visit:\nwww.sjerhombus.com.\n\n[Page 2]\n1 inch (2.5 cm)\nminimum from bottom\nof tank or from sludge\n0 inch (0 cm) liquid\nlevel measured from\napproximately this point\n4 inch (10.2 cm)\nminimum set level\nSHIELD: Connect to signal ground (low impedance)*\nRED: 12V power\nWHITE: Variable data signal\nVENT TUBE\n* If noise is observed in the frequency\nresponse, unplug the shield connection.\nBLACK: Ground\nPosition sensor at appropriate location on\npipe and secure sensor using provided hose\nclamp.\nDetermine the submergence depth and\noperating level ranges.\nTerminate sensor cable in the control panel,\nconnect wires to proper terminals as shown\non the control panel schematic.\nCaution: Do not overtighten clamp or tie straps.WARNING: To prevent erroneous measurements, do not\nallow the sensor diaphragm to come into contact with solid\nobjects or sludge. Do not use level measurements less than 4”\n(10.2 cm) for control or alarm purposes (dead band).\nCaution: If the level sensor wires are not connected properly, the\nC-Level™ signal output will not be correct. Level sensor and float\ncables need to run in separate conduit from pump and power\ncables.\nTie Straps\nWARNING: DO NOT\nkink or place cable\nunder hose clamp.\nDoing so may cause\nsensor to fail.\nWARNING: DO NOT\nsupport sensor by\nthe cable.\nRedundant off float\n(recommended)\nHigh water alarm float\n(recommended)\nFunctionally test the level measurement and\nensure proper operation of the system by\nfilling the tank.",
      "added_by": "added by the owner",
      "text_withheld": false
    },
    {
      "id": "f8af37dd-6a0d-4ba4-8f7f-c7b33b7aa184",
      "title": "Effluent pump manual: Myers ME50",
      "file_name": "ME50 pumps-manual.pdf",
      "kind": "PDF",
      "section": "Documents",
      "appendix": "Equipment manuals",
      "added": "2026-05-26",
      "size_bytes": 976583,
      "starred": false,
      "url": "https://qrchive.ca/api/files/f8af37dd-6a0d-4ba4-8f7f-c7b33b7aa184",
      "text_status": "ok",
      "text_chars": 36311,
      "text_url": "https://qrchive.ca/api/files/f8af37dd-6a0d-4ba4-8f7f-c7b33b7aa184/text",
      "text": null,
      "added_by": "added by the owner",
      "text_withheld": false
    },
    {
      "id": "b0d95ae5-381d-4a7c-b130-876eff16855f",
      "title": "Control panel manual: SJE Rhombus IFS",
      "file_name": "Rhombus-IFS-IV-Op-Manual-English.pdf",
      "kind": "PDF",
      "section": "Documents",
      "appendix": "Equipment manuals",
      "added": "2026-05-26",
      "size_bytes": 893712,
      "starred": true,
      "url": "https://qrchive.ca/api/files/b0d95ae5-381d-4a7c-b130-876eff16855f",
      "text_status": "ok",
      "text_chars": 25809,
      "text_url": "https://qrchive.ca/api/files/b0d95ae5-381d-4a7c-b130-876eff16855f/text",
      "text": null,
      "added_by": "added by the owner",
      "text_withheld": false
    },
    {
      "id": "600f43c1-31b6-435d-90cb-2a0a85c444ea",
      "title": "Maintenance checklist",
      "file_name": "Maintenance Checklist.pdf",
      "kind": "PDF",
      "section": "Documents",
      "appendix": null,
      "added": "2026-05-26",
      "size_bytes": 74945,
      "starred": true,
      "url": "https://qrchive.ca/api/files/600f43c1-31b6-435d-90cb-2a0a85c444ea",
      "text_status": "ok",
      "text_chars": 8552,
      "text_url": "https://qrchive.ca/api/files/600f43c1-31b6-435d-90cb-2a0a85c444ea/text",
      "text": "[Page 1]\nDate: Provider:\nOwner: System Type: Type 1 Sand Mound (Micro-Time Dosed)\nDDF: 2300 L/day ADF: 1150 L/day\nComponents:\nDispersal:\nSection Check Item Verification Task ☐ Pass / ☐ Fail / Notes\nHazards Be aware of electrical hazards, tripping/falling hazards from\nopen lids, protect bystanders, kids, dogs, etc.\n☐ OK ☐ Action ☐ N/A\nTank Protection Confirm continued protection of tanks — no traffic or structures\nover tanks, suitable surface drainage\n☐ OK ☐ Action ☐ N/A\nField Protection Confirm continued protection of dispersal field — no\nstructures, no heavy traffic, appropriate\nvegetation/landscaping, no erosion\n☐ OK ☐ Action ☐ N/A\nSurface No ponding, odors, or breakout risk over bed; cover soil intact\nand graded to shed runoff\n☐ OK ☐ Action ☐ N/A\nBaffles Check alignment, condition, and proper operation of inlet and\noutlet baffles\n☐ OK ☐ Action ☐ N/A\nFOG / Filter Clean fats/oil/grease from inlet baffle. Discuss any usage\nissues with owner.\n☐ OK ☐ Action ☐ N/A\nTrickle Flow Confirm no trickle flows when fixtures off (no leaking toilets,\ndripping faucets, groundwater infiltration)\n☐ OK ☐ Action ☐ N/A\nSludge / Scum Measure sludge + scum: must be ≤ ⅓ of first-compartment\nvolume. Pump out only if exceeded.\n☐ OK ☐ Action ☐ N/A\nBaffles Check alignment, condition, and proper operation of inlet and\noutlet baffles\n☐ OK ☐ Action ☐ N/A\nFOG / Filter Clean fats/oil/grease from inlet baffle. Inspect and clean\nPL250 effluent filter. Discuss any usage issues with owner.\n☐ OK ☐ Action ☐ N/A\nSludge / Scum Measure sludge + scum: must be ≤ ⅓ of first-compartment\nvolume of Galcon RKS1400LP/2. Pump out only if exceeded.\n☐ OK ☐ Action ☐ N/A\nSolids Assess solids in bottom of pump chamber — should be\nlittle/none, no foreign objects. Inspect effluent: type 1\ncharacteristics.\n☐ OK ☐ Action ☐ N/A\nPiping Confirm leak-free union and all piping in chamber. Note anti-\nsiphon / air-removal orifice on discharge piping.\n☐ OK ☐ Action ☐ N/A\nConduit Seal Confirm sealing of electrical conduit from control panel to\npump chamber (no moisture/gas passage to panel)\n☐ OK ☐ Action ☐ N/A\nFloats / Pump Pull and clean control floats and exposed pump/wiring. Test\nredundant HLA and redundant Off floats. Test external alarm\ntest/silence buttons.\n☐ OK ☐ Action ☐ N/A\nLeaks / Breakout Inspect dispersal area for any signs of leaks, surfacing\neffluent, or breakout\n☐ OK ☐ Action ☐ N/A\nObs Ports Inspect 2× infiltrative-surface and 2× basal observation ports\n(4\" Sch 40 PVC). Note any standing water or excessive\nponding.\n☐ OK ☐ Action ☐ N/A\nVents Inspect 2× Big 'O' passive vent risers — gooseneck and bug\nscreens intact, no obstructions\n☐ OK ☐ Action ☐ N/A\nSECTION 1: PRE-SERVICE NOTES & VISUAL INSPECTION\nLIFT TANK\nLS: 700 IG concrete (2 ch, existing) → Myers 10MD (115V, ½ HP) on Rhombus NEXT panel | ST: Galcon RKS1400LP/2 w/ PL250 | PC:\nGalcon RKP1000LP (4546 L) | Field Pump: Myers ME 50 (230V, ½ HP) | Field Panel: SJE Rhombus IFS Simplex\nSEPTIC TANK\nGENERAL\nDISPERSAL\nMAINTENANCE CHECKLIST — TYPE 1 SAND MOUND SEEPAGE BED SYSTEM\nSand mound seepage bed 4.2 × 14.0 m (1 zone, end-fed) | 6 laterals × 14 m (1.25\" Sch 40 PVC), 66 cm OC, 45 cm to edge | 108 orifices (⅛\"\n@ 78 cm, 12 o'clock w/ Polylok shields) | 30 cm mound sand + 30 cm pea gravel + 4 obs ports + 2× Big 'O' passive vent\nPUMP CHAMBER\n\n[Page 2]\nMAINTENANCE CHECKLIST — TYPE 1 SAND MOUND SEEPAGE BED SYSTEM\nPanel Condition SJE Rhombus IFS Simplex: weatherproof, accessible, no\ncorrosion, mounting secure\n☐ OK ☐ Action ☐ N/A\nManual Override Test the manual pump override function inside the control\npanel\n☐ OK ☐ Action ☐ N/A\nPanel Records Record cycle counts, elapsed run time, float errors, alarm\ncounts via In-Site\n☐ OK ☐ Action ☐ N/A\nFlow vs. ADF Cycles × 82 L/dose ≤ 1150 L/day ADF (DDF 2300 L/day). Flag\nif exceeding.\n☐ OK ☐ Action ☐ N/A\nLift Station Verify Lift Station (Myers 10MD on Rhombus NEXT) — HLA +\non/off floats, alarm function, demand-dose cycling\n☐ OK ☐ Action ☐ N/A\nConcerns Discuss any concerns with owner — alarms, smells, slow\ndrains, system usage changes\n☐ OK ☐ Action ☐ N/A\nRecommendations Provide owner with recommendations or follow-up actions\narising from this maintenance visit\n☐ OK ☐ Action ☐ N/A\nPhotos Photos of components, observation ports, and any issues\nidentified\n☐ OK ☐ Action ☐ N/A\nSection Check Item Verification Task ☐ Pass / ☐ Fail / Notes\nTanks Inspect all 3 tanks for leaks (lift station, septic tank, pump\nchamber). Watertight at risers/seams.\n☐ OK ☐ Action ☐ N/A\nPiping Check transport main, pressure main, and manifold\nconnections under pressure for leaks\n☐ OK ☐ Action ☐ N/A\nPressure Main Flush 2\" main w/ lateral valves closed, manifold cleanout open ☐ OK ☐ Action ☐ N/A\nLaterals Flush all six 1.25\" laterals individually, distal cleanout caps\noff\n☐ OK ☐ Action ☐ N/A\nManual Test Manually activate pump (override floats if needed); confirm\npump operation\n☐ OK ☐ Action ☐ N/A\nTimed Dosing Pump activates on timer (Override 51 min @ DDF / Primary\n102 min @ ADF), shuts off after 23 s\n☐ OK ☐ Action ☐ N/A\nDose Volume Dose volume measured against design (82 L). Verify by\ndrawdown ≈ 2 cm at 51 L/cm.\n☐ OK ☐ Action ☐ N/A\nCheck Valve No siphoning/backflow (check valve functional) ☐ OK ☐ Action ☐ N/A\nSection 1 Notes / Issues:\nOWNER\nINTERFACE\nELECTRICAL\n& CONTROLS\nFLUSH\nDISPERSAL\nSECTION 2: PERFORMANCE TESTING & FIELD FLUSH\nLEAK\nTESTING\nUse field-pump dosing to flush components, verify dose volume, and run squirt test before close-out.\nPUMP &\nDOSING\n\n[Page 3]\nMAINTENANCE CHECKLIST — TYPE 1 SAND MOUND SEEPAGE BED SYSTEM\nControl Setting Design (cm) C-Level / Float (cm) As-Found (cm)\nHigh Level Alarm 66 C-Level: 50 | Float: 76\nOverride Timer Enable 71 C-Level: 45 | Float: n/a\nPrimary Timer Enable 35 C-Level: 20 | Float: n/a\nRedundant Off / Low\nLevel 30 C-Level: 10 | Float: 25\nDose Timer (On) 23 s Run time per dose (constant ADF & DDF)\nRest Timer (Off) ADF: 102 min\nDDF: 51 min Primary 102 min @ ADF; Override 51 min @ DDF\nSection Check Item Verification Task ☐ Pass / ☐ Fail / Notes\nFloat Function Raise/lower each float (HLA + Off) to simulate levels —\nconfirm pump and alarm responses match\n☐ OK ☐ Action ☐ N/A\nC-Level Reading Confirm C-Level transducer reading matches measured liquid\ndepth − 15 cm (offset)\n☐ OK ☐ Action ☐ N/A\nAlarm Test Simulate high water — alarm activates (light/horn). Test alarm-\nsilence button.\n☐ OK ☐ Action ☐ N/A\nAuto Mode Confirm AUTO is set for both pump and alarm before leaving\nsite\n☐ OK ☐ Action ☐ N/A\nReset Errors Clear/log any error or alarm history; document elapsed run time\nand cycle count\n☐ OK ☐ Action ☐ N/A\nFilter Clean Zabel A300 12\"×20\" — pull, hose off, inspect for\ndamage/clogging, reinstall\n☐ OK ☐ Action ☐ N/A\nSmartFilter Alarm Test Polylok SmartFilter Control Switch — wired to high-level\nalarm input on field-pump panel\n☐ OK ☐ Action ☐ N/A\nDistribution Even distribution across all 6 laterals (1 zone, end-fed) ☐ OK ☐ Action ☐ N/A\nSquirt Test Install temp 1/8\" orifice caps at lateral cleanouts; squirt test\nwith all valves open. Record heights:\n☐ OK ☐ Action ☐ N/A\nRemove Caps Remove drilled test caps; ensure all cleanout caps in place;\nconfirm all lateral valves OPEN\n☐ OK ☐ Action ☐ N/A\nObs Ports Re-inspect obs ports post-flush — note any new ponding ☐ OK ☐ Action ☐ N/A\nBED\nTEST\nSection 2 Notes / Issues:\nAll heights from inside bottom of pump chamber. C-Level transducer offset = 15 cm above tank bottom (C-Level reading = float setpoint − 15 cm). Confirm setpoints match design or r\nFLOAT & CONTROL PANEL VERIFICATION — AS-FOUND vs. AS-RESET\nFLOAT &\nPANEL\nEFFLUENT\nFILTER\n\n[Page 4]\nMAINTENANCE CHECKLIST — TYPE 1 SAND MOUND SEEPAGE BED SYSTEM\nSection Check Item Verification Task ☐ Pass / ☐ Fail / Notes\nLids Secured After service, ensure all tank lids/risers properly secured (LS,\nST, PC)\n☐ OK ☐ Action ☐ N/A\nSite Tidy Tools/equipment removed; valve boxes covered; site left\nclean for owner\n☐ OK ☐ Action ☐ N/A\nOwner Brief Brief owner on findings, recommendations, and next\nmaintenance interval\n☐ OK ☐ Action ☐ N/A\nRecords Update maintenance log with cycle count, run time, dose\nvolume, alarms, panel readings\n☐ OK ☐ Action ☐ N/A\nReporting If ROWP problems arise, submit annual report to Island Health\n(per SSR / ROWP duties)\n☐ OK ☐ Action ☐ N/A\nSignature: Date:\nSystem has been serviced per the maintenance plan and is operating within design parameters. Any departures or follow-up actions are documented in the Notes/Issues\nsections above.\nFINAL SIGN-OFF\nFollow-up actions required (if any):\nSECTION 3: DOCUMENTATION & CLOSE-OUT\n_______________________________________ , Maintenance Provider\nCLOSE-OUT\nSection 3 Notes / Issues:",
      "added_by": "added by the owner",
      "text_withheld": false
    },
    {
      "id": "3e2bb9ff-353e-470c-a7b6-50379f65e36e",
      "title": "Design drawing: dispersal field",
      "file_name": "DD FIELD .pdf",
      "kind": "PDF",
      "section": "Documents",
      "appendix": null,
      "added": "2026-05-26",
      "size_bytes": 842623,
      "starred": true,
      "url": "https://qrchive.ca/api/files/3e2bb9ff-353e-470c-a7b6-50379f65e36e",
      "text_status": "ok",
      "text_chars": 1501,
      "text_url": "https://qrchive.ca/api/files/3e2bb9ff-353e-470c-a7b6-50379f65e36e/text",
      "text": "[Page 1]\nDESIGN DETAILS: SECTION VIEW OF DISPERSAL FIELD DETAILS\nLATERAL PIPE\nLANDSCAPE\nBOX NDS PRO\n150 mm\nFINISHED\nGRADE\nLATERAL\nCLEAN\nOUT\nCLEAN OUT ACCESS PORT\n50 mm (2.0 in) SCH. 40\nPVC TRANSPORT PIPE\nFROM PUMP CHAMBER\n32 mm (1.25 in) SCH. 40\nPVC LATERAL\n32 mm (1.25 in) SCH. 40\nPVC THREADED END CAP\n32 mm (1.25 in) SCH. 40\nLONG SWEEP 90 ELBOW\nOR 2x 45 ELBOW\n50 mm (2.0 in) SCH. 40\nLONG SWEEP 90 ELBOW\nOR 2x 45 ELBOW\n50 mm (2.0 in) SCH. 40\nPVC THREADED END CAP\nORIFICES LOCATED ON LATERALS @ 12 O'CLOCK POSITION. FIRST AND LAST ORIFICES AT 1/2 SPACING\nFROM THE MANIFOLD AND END CLEANOUT. LATERALS TO BE LAID LEVEL (+/- 5cm)\n4\" BIG 'O'\nPERFORATED\nPIPE BEDDED\nIN 12\" OF 1/2\"\nWASHED PEA\nGRAVEL\n1.25\" PVC\nDISPERSAL\nLATERALS\n2\" PVC\nPRESSURE\nMANIFOLD\n4\" SCH 40 PVC\n90 DEG ELBOW\n2x 4\" SCH 40 PVC\n90 DEG ELBOWS\nSTAINLESS\nSTEEL\nBUG SCREEN\n4\" SCH 40 PVC\nVERTICAL RISER\nMINIMUM OF 60 cm\nABOVE GRADE\nPVC GOOSENECK BASE BEDDED\nIN COMPACTED MOUND SAND\nMEDIA OR NATIVE SANDY LOAM\nCOVER SOIL\n390 mm\n780 mm\n390 mm\n14.0 m\n780 mm\n32 mm (1.25 in) SCH. 40\nPVC THREADED END CAP\n32 mm (1.25 in) SCH. 40\nLONG SWEEP 90 ELBOW\nOR 2x 45 ELBOW\nSECTION VIEW OF LATERAL PIPE SECTION VIEW OF PASSIVE VENTILATION\n50 mm (2.0 in) SCH. 40\nPVC MANIFOLD\nMANIFOLD CONNECTION TO LATERAL PIPES\nPOLYLOK\nORIFICE SHIELD\n18 PER INDIVIDUAL\nLATERAL (x6 LATERALS)\n32 mm (1.25 in) BALL VALVE\nTO BE ACCESSIBLE FROM\nSURFACE\nBEDDED IN\nPEA GRAVEL\nBASE\nCOVER SOIL\n50 mm (2.0 in) SCH. 40 TEE\nAND 2.0 in x 1.25 REDUCING BUSHING\n50 mm (2.0 in) SCH. 40\nPVC MANIFOLD",
      "added_by": "added by the owner",
      "text_withheld": false
    },
    {
      "id": "5ef73c2c-4ba1-4ec1-99ca-6d6522c72706",
      "title": "Design drawing: tanks",
      "file_name": "DD TANKS .pdf",
      "kind": "PDF",
      "section": "Documents",
      "appendix": null,
      "added": "2026-05-26",
      "size_bytes": 302095,
      "starred": true,
      "url": "https://qrchive.ca/api/files/5ef73c2c-4ba1-4ec1-99ca-6d6522c72706",
      "text_status": "ok",
      "text_chars": 663,
      "text_url": "https://qrchive.ca/api/files/5ef73c2c-4ba1-4ec1-99ca-6d6522c72706/text",
      "text": "[Page 1]\nDESIGN DETAILS: SECTION VIEW OF TANK DETAILS\nPUMP CHAMBER: RKP1000LP - 1 CHAMBER\nSEPTIC TANK: RKS1000LP/2 - 2 CHAMBER\nOUTLET\nTO FIELD\nINLET OUTLET\nTO PUMP\nCHAMBER\nINLET\nOFF FLOAT\nHIGH LEVEL ALARM FLOAT\nC-LEVEL SENSOR\nCHECK VALVE\nZABEL A300 1/32\"\n12\"x20\" EFFLUENT FILTER\nPVC SCH. 40 32 mm (1.25 in) FLOAT TREE\nPVC SCH 40\nBALL VALVE\nPVC SCH.\n40 UNION\n3/16\" ORIFICE HOLE\nLIFT STATION: 700 IG 2 CHAMBER\nOUTLET TO\nFIELD SEPTIC\nTANK\nINLET\nHIGH LEVEL ALARM FLOAT\nON/OFF FLOAT\nFLOAT\nSWITCH\nCABLE\nWEIGHT\nTETHER LENGTH\n10 CM (4 INCHES)\nZABEL A300 FILTER CARTRIDGE\nCHECK VALVE\nPVC SCH 40\nBALL VALVEPVC SCH.\n40 UNION\n3/16\" ORIFICE HOLE\nFILTER ACCESS HANDLE\nFILTER SUPPORT\nARM",
      "added_by": "added by the owner",
      "text_withheld": false
    },
    {
      "id": "b0999bb0-b276-4e78-b8a0-c19c090d6a1a",
      "title": "Sand fill placed",
      "file_name": "IMG_5218.jpeg",
      "kind": "photo",
      "section": "Photos",
      "appendix": "Install photos",
      "added": "2026-05-26",
      "size_bytes": 5568180,
      "starred": false,
      "url": "https://qrchive.ca/api/files/b0999bb0-b276-4e78-b8a0-c19c090d6a1a",
      "text_status": null,
      "text_chars": null,
      "text_url": null,
      "text": null,
      "added_by": "added by the owner",
      "text_withheld": false
    },
    {
      "id": "fed59b42-72b2-4025-8de3-aeca3895ec17",
      "title": "Homeowner guide: Let's Get Septic Smart",
      "file_name": "Lets Get Septic Smart Homeowner Guide.pdf",
      "kind": "PDF",
      "section": "Documents",
      "appendix": null,
      "added": "2026-05-26",
      "size_bytes": 494795,
      "starred": true,
      "url": "https://qrchive.ca/api/files/fed59b42-72b2-4025-8de3-aeca3895ec17",
      "text_status": "ok",
      "text_chars": 24095,
      "text_url": "https://qrchive.ca/api/files/fed59b42-72b2-4025-8de3-aeca3895ec17/text",
      "text": null,
      "added_by": "added by the owner",
      "text_withheld": false
    },
    {
      "id": "ed10c64a-5875-4d33-b994-6b24c9673c38",
      "title": "Level settings screen",
      "file_name": "IMG_6643.JPG",
      "kind": "photo",
      "section": "Photos",
      "appendix": "Install photos",
      "added": "2026-05-26",
      "size_bytes": 2164906,
      "starred": false,
      "url": "https://qrchive.ca/api/files/ed10c64a-5875-4d33-b994-6b24c9673c38",
      "text_status": null,
      "text_chars": null,
      "text_url": null,
      "text": null,
      "added_by": "added by the owner",
      "text_withheld": false
    },
    {
      "id": "cb411067-f799-412d-b3e6-7cb543a9a91b",
      "title": "Pump cycle counts",
      "file_name": "IMG_6638.JPG",
      "kind": "photo",
      "section": "Photos",
      "appendix": "Install photos",
      "added": "2026-05-26",
      "size_bytes": 2009691,
      "starred": false,
      "url": "https://qrchive.ca/api/files/cb411067-f799-412d-b3e6-7cb543a9a91b",
      "text_status": null,
      "text_chars": null,
      "text_url": null,
      "text": null,
      "added_by": "added by the owner",
      "text_withheld": false
    },
    {
      "id": "195b57d6-87cf-49f9-bbf6-d60be58aaffa",
      "title": "Lids and panel",
      "file_name": "IMG_6636.JPG",
      "kind": "photo",
      "section": "Photos",
      "appendix": "Install photos",
      "added": "2026-05-26",
      "size_bytes": 10641285,
      "starred": false,
      "url": "https://qrchive.ca/api/files/195b57d6-87cf-49f9-bbf6-d60be58aaffa",
      "text_status": null,
      "text_chars": null,
      "text_url": null,
      "text": null,
      "added_by": "added by the owner",
      "text_withheld": false
    },
    {
      "id": "59d53b00-986e-40c9-9bf0-c973dabd9c5a",
      "title": "Finished mound",
      "file_name": "IMG_6588.JPG",
      "kind": "photo",
      "section": "Photos",
      "appendix": "Install photos",
      "added": "2026-05-26",
      "size_bytes": 9399701,
      "starred": false,
      "url": "https://qrchive.ca/api/files/59d53b00-986e-40c9-9bf0-c973dabd9c5a",
      "text_status": null,
      "text_chars": null,
      "text_url": null,
      "text": null,
      "added_by": "added by the owner",
      "text_withheld": false
    },
    {
      "id": "d68033dd-7932-40f1-a115-a3856fab3f4f",
      "title": "Effluent filter riser",
      "file_name": "IMG_6584.JPG",
      "kind": "photo",
      "section": "Photos",
      "appendix": "Install photos",
      "added": "2026-05-26",
      "size_bytes": 4961270,
      "starred": false,
      "url": "https://qrchive.ca/api/files/d68033dd-7932-40f1-a115-a3856fab3f4f",
      "text_status": null,
      "text_chars": null,
      "text_url": null,
      "text": null,
      "added_by": "added by the owner",
      "text_withheld": false
    },
    {
      "id": "89f292bf-da59-43ae-94e8-43d7094e7516",
      "title": "Control panel mounted",
      "file_name": "IMG_5270.jpeg",
      "kind": "photo",
      "section": "Photos",
      "appendix": "Install photos",
      "added": "2026-05-26",
      "size_bytes": 8423583,
      "starred": false,
      "url": "https://qrchive.ca/api/files/89f292bf-da59-43ae-94e8-43d7094e7516",
      "text_status": null,
      "text_chars": null,
      "text_url": null,
      "text": null,
      "added_by": "added by the owner",
      "text_withheld": false
    },
    {
      "id": "c67add8c-1e3f-4855-a3fa-931a24a310f7",
      "title": "Finished sand cap",
      "file_name": "IMG_5265.jpeg",
      "kind": "photo",
      "section": "Photos",
      "appendix": "Install photos",
      "added": "2026-05-26",
      "size_bytes": 5158528,
      "starred": false,
      "url": "https://qrchive.ca/api/files/c67add8c-1e3f-4855-a3fa-931a24a310f7",
      "text_status": null,
      "text_chars": null,
      "text_url": null,
      "text": null,
      "added_by": "added by the owner",
      "text_withheld": false
    },
    {
      "id": "dee03df9-54db-466c-afe2-a6d21f444f10",
      "title": "Laterals side view",
      "file_name": "IMG_5243.jpeg",
      "kind": "photo",
      "section": "Photos",
      "appendix": "Install photos",
      "added": "2026-05-26",
      "size_bytes": 5247074,
      "starred": false,
      "url": "https://qrchive.ca/api/files/dee03df9-54db-466c-afe2-a6d21f444f10",
      "text_status": null,
      "text_chars": null,
      "text_url": null,
      "text": null,
      "added_by": "added by the owner",
      "text_withheld": false
    }
  ],
  "notes": [
    "The files are the record. This listing is a guide to them, generated from the archive when it was requested.",
    "Open a file with its link. Where a PDF also has a text link, that link returns the text inside the PDF as plain text. Short documents are printed in full at the end of this listing.",
    "Photos (37) and video (1) are listed by name only — nothing here describes what they show."
  ],
  "generated_at": "2026-10-16T15:26:49.086Z"
}